Testing the Broiling Element:

  1. Before repairs or testing can begin you must disconnect the electricity at the fuse panel, at the circuit breaker panel, or by pulling the plug. Make sure the power is off before proceeding. A jolt from 220 volts can be fatal, use caution!
  2. To access the broil element located on the roof of the oven cavity, first open the oven and remove the oven racks. Remove the screws that secure the element to the oven, remove the holding brackets from the element and slide the element forward.
  3. There is normally a small amount of excess wiring attached to the terminals on the element that allow a little room for maneuverability (you may have to tilt the element to get the terminals through the holes). Look for loose or disconnected wires and if there is no sign of burning; reconnect the wiring to the back of the terminal. If a terminal end is damaged, replace it with a terminal end designed specifically for oven use only.
  4. To test the broil element, remove the wires from the broil element terminals by removing the screws from the terminal or pulling the wires off the broil element terminal. Remember to label the wires for reinstallation.
  5. Visually check the entire element for signs of burn.
  6. Test the broiler element for continuity. Using the ohmmeter, set the range scale on R x 1 and place the probes on the element terminals. There should be continuity, with readings ranging from 19 to 115 ohms, however readings will vary from manufacturer to manufacturer and according to unit size and the wattage, be sure to check your manual for the manufacturer's specifications.
  7. If there are any signs of element burning, or if there is no continuity, replace the element.
  8. To test for a grounded broil element, place one probe on the element outer surface and the other on the element terminal as in the ground test for the baking element. If continuity exists, the element has shorted and should be replaced. Be sure to test both terminals.
  9. To test a dual broil element, remove the wires from their terminals. Using the ohmmeter, set the range on R x 1. Place the probes on terminals A and C to check for continuity, followed by terminals B and C. To test for a grounded element, place one probe on the element outer surface. With the other probe, touch terminal A, followed by B and then C. If continuity exists, the element has shorted and should be replaced.
  10. To install a new broil element, simply reverse the disassembly procedures and reassemble, being sure to follow the wiring diagram and install the wires to the correct terminals
    REMEMBER YOU ARE WORKING WITH 220 VOLTS - USE EXTREME CAUTION!!!